COMPANY PROFILE
Output value of China's medical equipment maintained the 90s since the 20th century, since has maintained growth, the average growth rate has maintained remained 12% -15% leve.
Tel: 8610-85810128
Fax: 8610-85810128
E-mail:
dxac1234@aliyun.com
snlaser2010@hotmail.com
Mobile: 13520875623

HOME >> PRODUCT
Portable laser SN-660


PERIODONTICS

 

   1  Pre and post periodontal scraping; 

   2  Reduction of inflammation in gingivitis; 

   3  Dentine hypersensitivity; 

 

ENDODONTICS

 

   1  Differential diganosis; 

   2  Abscess drainage; 

   3  Root canal post-instrumentation; 

   4  Apical and periapical lesions repair; 

 5  Pulp inflammation reduction; 

   6  Lesions caused by isolation champs

 

OCCLUSALF SURFACE FACIAL SURGERY AND   

 TRAUMATOLOGY

 

   1  Immediate and mediate postoperative for analgesia and to stimulate the

      traumatized tissues repair;  

   2  In the immediate and mediate postoperative of surgeries on soft tissues; 

   3  In cases of the pericoronitis and alveolitis; 

   4  In cases of paresthesia; 

 

 IMPLANTODONTICS

   1  Pre, trans and postoperative; 

   2  In cases of paresthesia; 

   3  Osteointegration acceleration;

 

 ORTHODONTICS

   1  Pain relief after the device activation; 

   2  Stimulation for apposition and osseous absorption, accelerating the 

      orthodontic movement;  

   3  Cicatrization of lesions caused by influenza( brackets); 

   4  Auxiliary in the adaptation of TMA and associate muscle system

 

PEDIATRIC DENTISTRY

   1  The same as for dentistry; 

   2  Reduction of discomfort during dental eruption;

 

   ESTOMALOGY

 

  Lesions of known etiology, such as aphthae, herpes simplex and zoster, 

  mucositis, geographic tongue, linchen planus;

 

FIXED DENTAL PROSTHESIS

  Pre-cementation of prosthetic pieces on pulped teeth; 

  Relief from discomfort caused by the post casting retracting thread

 

OCCLUSION

  1  Auxiliary in the treatment of the temporomandibular dysfunction (TMD),

  2  promotion relief from articular and muscular pain, improvement of the 

     buccal opening and closing movements; 

  3  Analgesia in acute and chronic cases;

 

Operation

  1  Put the plug into electric socket of 110V-240V

  2  Choose the time for your need 

  3  Operational Mode : Change mode button to continuous and pulse

 

Wavelength

 660nm ±10%

Net Weight

  250g

Output power

 ≥ 60 mw

Operational mode

Continue/pulse(2Hz)

Laser  class

B

Size

θ25×210 mm

Time set

10s,20s,40s,80s

Supply voltage

110V-240V/50-60Hz

 

660.JPG